Ariston Aco Combi 27Kw Boiler
Wall-hung High Efficiency gas combination boiler
Natural Gas
Product Characteristics
ACO is a compact and easy to insall with plenty of hand and tool room and easy access to all connections from the front. This all new high efficiency boiler has a comprehensive specification including electronic ignition, automatic by-pass, anti scale, anti-frost device and self-diagnostics sequence. Ariston's standard water and gas connections jig-kit is supplied as standard with the ACO Combi (along with a filing loop) - this means that the new ACO combi can be fitted as a replacement for an older Ariston combi on it's existing Jig-kit.
ACO boasts the very latest in technology. A bespoke PCB, designed and produced in-house by Ariston, which allows true flexibility of boiler function. At the heart of the boiler is a new stainless steel primary heat exchanger, produced using the most advanced automotive technology, which has been designed for long life. The ACO has also been designed from the outset to be compatible with Ariston's futuristic remote diagnostics package (currently under development) which will change the way boiler servicing is carried out.
Product Features
|
Main Technical Information |
|
Heigth |
mm |
750 |
|
Width |
mm |
450 |
|
Depth |
mm |
280 |
|
Characteristics |
|
- The First UK Boiler with a FREE 5 year guarantee
- SEDBUK Band A
- Available in three outputs of 27 and 32kW (with a larger model available in 2005)
- Compact dimentions 750x450x280 mm
- Comfort Switch (Pre-heat function) guaranteeing hot water to the outlet in less than 5 seconds (depending upon installation)
- Auto-diagnostic system and integrated advanced controls built in to advanced PCB with microprocessor
- Simple maintenance with easy access all from the front of the appliance
- Two speed modulating pump: decreases noise and increases efficiency
- Anti-frost device
- Anti-scale device
- Anti seizing device for the pump
- Built in automatic by-pass
- built in mechanical time clock
- Multiple flueing options: up to 4m coaxial and 40m twin pipe
- Split exhaust and intake pipes for built-in combustion analysis
- Includes jig-kit and filling loop
- Optional outdoor sensor: regulated heating temperature automatically increasing efficiency
|
Internal View |
|
|
|
|
Legend:
-
Coaxial flue connector
-
Mixer
-
Fan
-
Igniter
-
Burner
-
Ignition and detection electrode
-
Manual air release valve
-
Primary flow NTC probe
-
Main heat exchanger (aluminium)
-
Electrical bow containing PCB
-
By-pass
-
3 bar saftey valve
-
Control panel
-
Secondary heat exchanger
-
Gas valve
-
Domestic hot water flow switch
-
Pump
-
3-way motorised valve
-
Condensate trap
-
Condensate trap tube
-
Condensate collector
-
Primary return NTC probe
-
Combustion chamber
-
Integral expansion vessel
-
Rear condensate trap
-
Air pressure switch
-
Flue gas analysis point | |
|
Technical Data |
|
Power |
|
Heat input min (net) |
kW |
8,9 |
|
Heat input min (net) |
Btu/h |
30400 |
|
Heat input max (net) |
kW |
25,5 |
|
Heat input max (net) |
Btu/h |
87000 |
|
Heat output min |
kW |
7,7 |
|
Heat output min |
Btu/h |
26300 |
|
Heat output max |
kW |
22,5 |
|
Heat output max |
Btu/h |
76800 |
|
Heat output D.H.W max |
kW |
27 |
|
Heat output D.H.W max |
Btu/h |
92100 |
|
Efficiency |
|
SEDBUK Rating |
|
A |
|
Characteristics |
|
Maximum exhaust gas temperature |
°C |
72 |
|
Minimum ambient temperature |
°C |
5 |
|
NOx class |
|
5 |
|
O2 content |
% |
4,3 |
|
Gas inlet pressure - Natural Gas (G20) |
mbar |
20 |
|
Pressure loss through boiler (max) (DT=20°C) |
mbar |
200 |
|
Residual head of system |
bar |
0,2 |
|
Maximum heating pressure |
bar |
3 |
|
Maximum water content of system |
l |
130 |
|
Maximum domestic hot water pressure |
bar |
6 |
|
Minimum domestic hot water pressure |
bar |
0,2 |
|
Built-in expansion vessel capacity |
l |
7 |
|
Gas consumption at nominal capacity G20 (15°C; 1013 mbar) |
m³/h |
2,43 |
|
GC number |
|
47-116-34 |
|
Heigth |
mm |
750 |
|
Width |
mm |
450 |
|
Depth |
mm |
280 |
|
Weight |
kg |
40 |
|
Performance |
|
Maximum heating temperature |
°C |
82 |
|
Minimum heating temperature |
°C |
20 |
|
Maximum domestic hot water temperature |
°C |
56 |
|
Minimum domestic hot water temperature |
°C |
36 |
|
D.H.W flow rate (DT=35°C) |
gal/min |
2,4 |
|
D.H.W flow rate (DT=35°C) |
l/min |
10,8 |
|
Electrical data |
|
Supply voltage |
V |
230 |
|
Supply frequency |
Hz |
50 |
|
Power consumption |
W |
118 |
|
Protection grade of electrical system |
IP |
24D |
|
Internal fuse rating |
|
2A Fast Fuse |


| Residual Head |
|

|
| |
| Hydraulic Schematic |
|

Legend
C Gas inlet 20
|
You will need Adobe Acrobat Reader to view the PDF document. Please click on the RED sign to download
Sriston Installation and User Manual
|