0 item(s) in a bag  Total: £0.00- Checkout
Home   Careers   Shopping Terms   Contact Us About Us   Links   Order Tracking Invoice Printer   View Shopping Cart  
 Ariston Aco System 32 RFFI Boiler
Ariston Aco System 32 RFFI Boiler
Ariston Aco System 32 RFFI Boiler
 
 Price
Your Price: £598.99
£528.75
 
Choose Options & Quantity  
Coaxial Systems 60/100 Horizontal Coaxial Kit - 1000mm [+£57.53]
Horizontal Coaxial Kit + Vertical Starter [+£60.40]
90 Degrees Coaxial Elbow [+£30.20]
45 Degrees Coaxial Elbow (pack of 2) [+£50.34]
Coaxial Extension - 1000mm [+£32.41]
Coaxial Extension - 500mm [+£19.65]
Coaxial Systems 80/125 Horizontal Coaxial Kit + Adaptor 80/125 [+£54.36]
90 Degrees Coaxial Elbow 80/125 [+£36.24]
45 Degrees Coaxial Elbow 80/125 [+£30.20]
Coaxial Extension 80/125 - 1000mm [+£48.32]
Coaxial Extension 80/125 - 500mm [+£34.23]
Quantity
 Description

Ariston Aco System 32 RFFI Boiler

 
 
 
     
 
Wall-hung High Efficiency gas combination boiler
Natural Gas
 
 
Product Characteristics
 
ACO is compact and easy to install with pleanty of hand and tool room and easy access to all connections from the front. This all-new high efficiency boiler has a comprehensive specification including electronic ignition, automatic by-pass, anti-scale, anti-frost device and self-diagnostics sequence.

ACO boasts the very latest in technology. A bespoke PCB, designed and produed in-house by Ariston, allows true flexibility of boiler function. At the heart of the boiler is a new aluminium-silicon primary heat exchanger

 
Product Features

 

  • Electronic ignition
  • Anti-scale device
  • Anti-frost device
  • Low Nox
  • Insufficient system pressure shutdown
  • Automatic bypass
  • Fully modulating
  • C.H. Temperature adjustment
  • P.C.B with Microprocessor
  • Combustion analysis device
  • High efficiency
  • Outdoor sensor
  • Integral auto-diagnostics

 

Main Technical Information
Heigth
mm
750
Width
mm
450
Depth
mm
280

Characteristics

  • The first UK boiler with a FREE 5 Year guarantee
  • SEDBUK Band A
  • Available in two outputs of 27 and 32kW 
  • Compact dimentions 750x450x280mm
  • Auto-diagnostic system and integrated advanced controls built in to advanced PCB with microprocessor
  • Simple maintenance with easy access all from front of appliance
  • Two speend modulating pump: decreases noise and increases efficiency
  • Built in system components: pump and expansion vessel
  • Anti-frost device
  • Anti-scale device
  • Anti seizing device for the pump
  • Built in automatic by-pass
  • Multiple flueing options: up to 4m coaxial and 40m twin pipe
  • Split exhaust and intake pipes for built-in combustion analysis
  • Optional outdoor sensor: regulated heating temperature automatically increasing efficiency
  • Guarantee extendable year on year for life of boiler after first free 5 years
  • Designed for connection to any indirect hot water cylinder (preferably Ariston unvented cylinder)
 
Internal View
 
 
Legend:
 
  1. Coaxial flue connector
  2. Mixer
  3. Fan
  4. Igniter
  5. Burner
  6. Ignition and detection electrode
  7. Manual air release valve
  8. Primary flow NTC probe
  9. Main heat exchanger (aluminium)
  10. Electrical box containing PCB
  11. By-pass
  12. 3 bar saftey valve
  13. Control panel
  14. Gas valve
  15. Pump
  16. Condensate trap
  17. Condensate trap tube
  18. Condensate collector
  19. Primary reurn NTC Probe
  20. Combustion chamber
  21. Integral expansion vessel
  22. Rear condensate collector
  23. Air pressure switch
  24. Flue gas analysis ports
 
Technical Data
Power
   Heating capacity max kW    95500
   Heat input min (net) kW    10,5
   Heating capacity max Btu/h    28
   Heat input min (net) Btu/h    35800
   Heat input max (net) kW    25,7
   Heat input max (net) Btu/h    87000
   Heat output min kW    9,5
   Heat output min Btu/h    32400
Efficiency
   SEDBUK Rating A
Characteristics
   Minimum ambient temperature °C    5
   NOx class 5
   CO2 content % 9.8
   Gas inlet pressure - Natural Gas (G20) mbar    20
   Pressure loss through boiler (max) (DT=20°C) mbar    200
   Residual head of system bar    0,2
   Maximum heating pressure bar    3
   Maximum water content of system l    130
   Built-in expansion vessel pre-charge pressure bar    1
   Maximum domestic hot water pressure bar 6
   Built-in expansion vessel capacity l    6
   GC number 47-116-35
   Heigth mm    750
   Width mm    450
   Depth mm    280
   Weight kg    42
Electrical data
   Supply voltage V    230
   Supply frequency Hz    50
   Protection grade of electrical system IP 24D
   Internal fuse rating 3.15A Slow
 
 
Legend:
 
A - Central heating flow
C - Gas Inlet

D - Central heating return

F - Flue 

   
Sriston Installation and User Manual
 
 
 