Ariston MicroGENUS HE 32 Boiler 30.5kW 32MFFI
Wall hung high efficiency gas combination boiler natural gas boiler
Product Features
- Mechanical Time Clock
- Filling Loop
- Anti-Frost Device
- By-pass and integral diagonostics
- SEDBUK Band B
-
BTU/H 104,000
Wall hung high efficiency gas combination boiler Natural Gas
Product Characteristics
The microGENUS HE is a direct evolution of the familiar microGENUS range, which is now one of the UK's best selling gas boilers. The microGENUS HE is SEDBUK Band B rated boiler which is fully compliant to the latest building regulations. The microGENUS HE achieves this level of efficiency by incorporating an additional latent heat exchanger or recuperator, which significantly increases efficiency by extracting heat from the flue gases. The benifit of this is that it is based on existing technology and offers installers known boiler layout whilst meeting the requirments of the latest regulatory changes.
|
Main Technical Information |
|
Heigth |
mm |
700 |
|
Width |
mm |
400 |
|
Depth |
mm |
315 |
MICROGENUS HE 24 MFFI
|
Characteristics |
|
-
SEDBUK Band B - Complies with latest building regulations
-
Available in three outputs
-
Fully modulating in C.H/D.H.W with an accuracy to +/- 1°C
-
Auto-diagnostic system
-
Comfort Switch (pre-heat function)
-
High D.H.W flow rates up to 12.5l/min (2.8 gal/min) (30.5 kW 104,000 Btu/h)
-
Anti-frost device
-
Anti-scale device
-
Anti seizing device for the pump
-
Built-in automatic by-pass
-
Built-in automatic time clock
-
Built-in condensate trap accessible from outside of the boiler casing
-
Split exhaust and intake pipes for built-in combustion analysis
-
Optional outdoor sensor: regulates the heating temperature automatically
-
D.H.W stainless steel plate heat exchanger guaranteed for 5 years
-
2 year manufacturer's guarantee
-
Guarantee extendable up to 5 years
|
|
|
Legend:
-
Flue Connector
-
Air intake (Twin Flue)
-
Air pressure swich
-
Fan
-
Combustion chamber hood
-
Main heat exchanger
-
Safety thermostat
-
C.H flow temperature probe
-
Combustion chamber
-
Detection electrodes
-
Ignition electrodes
-
Motorised diverter valve
-
Insulated secondary heat exchanger
-
DHW temperature probe
-
Pump pressure switch
-
Gas valve
-
Spark generator
-
DHW flow switch
-
Circulation pump with automatic air release valve
-
3 bar saftey valve
-
Burner
-
C.H return temperature probe
-
Expansion vessel
-
Venturi tubes
-
Latent heat exchanger (recuperator)
-
Combustion analysis intake |
Technical Data
|
Technical Data |
| Power |
| Heat input min (net) |
kW |
13,3 |
| Heat input min (net) |
Btu/h |
45400 |
| Heat input max (net) |
kW |
35 |
| Heat input max (net) |
Btu/h |
119400 |
| Heat output min |
kW |
11,3 |
| Heat output min |
Btu/h |
38600 |
| Heat output max |
kW |
30,5 |
| Heat output max |
Btu/h |
104000 |
| Efficiency |
| SEDBUK Rating |
|
B |
| Characteristics |
| Exhaust gas temperature at nominal capacity |
°C |
64,5 |
| Minimum ambient temperature |
°C |
5 |
| Gas inlet pressure - Natural Gas (G20) |
mbar |
20 |
| Pressure loss through boiler (max) (DT=20°C) |
mbar |
200 |
| Residual head of system |
bar |
0,25 |
| Maximum heating pressure |
bar |
3 |
| Maximum water content of system |
l |
130 |
| Built-in expansion vessel pre-charge pressure |
bar |
0,7 |
| Maximum domestic hot water pressure |
bar |
6 |
| Minimum domestic hot water pressure |
bar |
0,2 |
| D.H.W minimum flow rate |
l/min |
2,5 |
| Built-in expansion vessel capacity |
l |
7 |
| Gas consumption at nominal capacity G20 (15°C; 1013 mbar) |
m³/h |
3,33 |
| GC number |
|
47-116-39 |
| Heigth |
mm |
700 |
| Width |
mm |
400 |
| Depth |
mm |
315 |
| Weight |
kg |
39 |
| Performance |
| Maximum heating temperature |
°C |
82 |
| Minimum heating temperature |
°C |
38 |
| Maximum domestic hot water temperature |
°C |
56 |
| Minimum domestic hot water temperature |
°C |
36 |
| D.H.W flow rate (DT=35°C) |
gal/min |
2,8 |
| D.H.W flow rate (DT=35°C) |
l/min |
12,5 |
| Electrical data |
| Supply voltage |
V |
230 |
| Supply frequency |
Hz |
50 |
| Power consumption |
W |
165 |
| Protection grade of electrical system |
IP |
X4D |
| Internal fuse rating |
|
FAST 2 AT |


Legend:
A Central heating flow Ø 3/4" BSP B Domestic hot water outlet Ø 1/2"" BSP C Gas inlet Ø 3/4" BSP D Domestic hot water inlet Ø 1/2" BSP E Central heating return Ø 3/4" BSP F Flue (Ø mm)
| Residual Head |
 |
|
| Hydraulic Schematic |

| |