Ariston Microgenus II 24 MFFI Boiler
Compact wall-hung gas combination boiler, room sealed combustion chamber 24,6 kW / 83900 Btu/h, Fan flued, Natural Gas
microGENUS II combines the most advanced heating and domestic hot water production technologies in one compact unit, with tiny dimentions of just 700 x 400 x 300 mm, it can be installed almost anywhere.
Reliable, quiet, durable and hard working, this boiler looks great and offers three different outputs to suit most needs.
Guarantee: 2 Year Guarantee (extended up to 5 years).
|
Main Technical Information |
|
Usable thermal power max |
kW |
24,6 |
|
Heigth |
mm |
700 |
|
Width |
mm |
400 |
|
Depth |
mm |
300 |
|
Characteristics |
|
-
Compact dimentions (300x400x700mm)
-
Available in 3 outputs of 24.6 kW, 28.1 kW and 31.0 kW
-
Fully modulating in C.H./D.H.W. with an accuracy to
-
Auto-diagnostic system and integrated control in P.C.B
-
Government standard assessment procedure (SAP) efficiency rating up to 80.3%
-
Comfort Switch (pre heat function) guaranteeing hot water at the outlet in less than 5 seconds
-
High D.H.W flow rates up to 12.7 l/min (2.8 gal/min) (31 kW - 105800 Btu/h version)
-
Anti-frot device
-
Anti-scale device
-
Anti-seizing device for the pump
-
Built-in mechanical time clock
-
Coaxial flue system up to 4m, twin pipe system up to 30m
-
split exhust and intake pipes for built-in combustion analysis
-
Optional outdoor sensor: regulates the heating temperature automatically
-
D.H.W Stainless steel plate heat exchanger guaranteed for 5 years
|
|
Technical Data |
|
Power |
|
Heating capacity max |
kW |
26,5 |
|
Heating capacity max |
Btu/h |
90400 |
|
Heating capacity min |
kW |
11 |
|
Heating capacity min |
Btu/h |
37500 |
|
Usable thermal power max |
kW |
24,6 |
|
Usable thermal power max |
Btu/h |
83900 |
|
Usable thermal power min |
kW |
10 |
|
Usable thermal power min |
Btu/h |
34100 |
|
Characteristics |
|
Heat loss to the casing (DT=50°C) |
% |
0,1 |
|
Heat loss through the flue when burner on |
% |
6,9 |
|
Heat loss through the flue when burner off |
% |
0,4 |
|
Maximum exhaust discharge (natural gas) |
kg/h |
61.9 |
|
Exhaust gas temperature at nominal capacity |
°C |
0117,6 |
|
Minimum ambient temperature |
°C |
5 |
|
Gas inlet pressure - Natural Gas (G20) |
mbar |
20 |
|
Gas inlet pressure - LPG (G30) |
mbar |
28 |
|
Gas inlet pressure - LPG (G31) |
mbar |
30 |
|
Residual discharge head |
mbar |
1,65 |
|
Pressure loss through boiler (max) (DT=20°C) |
mbar |
200 |
|
Maximum heating pressure |
bar |
3 |
|
Maximum water content of system |
l |
130 |
|
Built-in expansion vessel pre-charge pressure |
bar |
1 |
|
Maximum domestic hot water pressure |
bar |
6 |
|
Minimum domestic hot water pressure |
bar |
0,2 |
|
D.H.W minimum flow rate |
l/min |
2,5 |
|
Built-in expansion vessel capacity |
l |
6 |
|
Gas consumption at nominal capacity G20 (15°C; 1013 mbar) |
m³/h |
2,8 |
|
Gas consumption G30 (15°C; 1013 mbar) |
kg/h |
2,09 |
|
Gas consumption G31 (15°C; 1013 mbar) |
kg/h |
2,06 |
|
Heigth |
mm |
700 |
|
Width |
mm |
400 |
|
Depth |
mm |
300 |
|
Performance |
|
Maximum heating temperature |
°C |
82 |
|
Minimum heating temperature |
°C |
38 |
|
Maximum domestic hot water temperature |
°C |
56 |
|
Minimum domestic hot water temperature |
°C |
36 |
|
D.H.W flow rate (DT=35°C) |
gal/min |
2,2 |
|
Electrical data |
|
Supply voltage |
V |
230 |
|
Power consumption |
W |
125 |
|
Protection grade of electrical system |
IP |
X4D |
|
Internal fuse rating |
|
FAST 2 AT |
Technical Drawing
Legend:
A Central heating flow Ø 3/4" BSP B Domestic hot water outlet Ø 1/2"" BSP C Gas inlet Ø 3/4" BSP D Domestic hot water inlet Ø 1/2" BSP E Central heating return Ø 3/4" BSP F Flue (Ø mm)
|
Residual Head |
|
(Image not available)
|
|
|
|
Hydraulic Schematic |
|
Legend:
ACentral heating flow Ø 3/4" BSP B Domestic hot water outlet Ø 1/2"" BSP C Gas inlet Ø 3/4" BSP D Domestic hot water inlet Ø 1/2" BSP E Central heating return Ø 3/4" BSP F Flue (Ø mm) | |