Ariston Microgenus II 28 MFFI Boiler
Compact wall-hung gas combination boiler, room sealed combustion chamber 24,6 kW / 83900 Btu/h, Fan flued, Natural Gas
microGENUS II combines the most advanced heating and domestic hot water production technologies in one compact unit, with tiny dimentions of just 700 x 400 x 300 mm, it can be installed almost anywhere.
Reliable, quiet, durable and hard working, this boiler looks great and offers three different outputs to suit most needs.
Guarantee: 2 Year Guarantee (extended up to 5 years).
|
Main Technical Information |
|
Usable thermal power max |
kW |
28,1 |
|
Heigth |
mm |
700 |
|
Width |
mm |
400 |
|
Depth |
mm |
300 |
|
Characteristics |
|
-
Compact dimentions (300x400x700mm)
-
Available in 3 outputs of 24.6 kW, 28.1 kW and 31.0 kW
-
Fully modulating in C.H./D.H.W. with an accuracy to
-
Auto-diagnostic system and integrated control in P.C.B
-
Government standard assessment procedure (SAP) efficiency rating up to 80.3%
-
Comfort Switch (pre heat function) guaranteeing hot water at the outlet in less than 5 seconds
-
High D.H.W flow rates up to 12.7 l/min (2.8 gal/min) (31 kW - 105800 Btu/h version)
-
Anti-frot device
-
Anti-scale device
-
Anti-seizing device for the pump
-
Built-in mechanical time clock
-
Coaxial flue system up to 4m, twin pipe system up to 30m
-
split exhust and intake pipes for built-in combustion analysis
-
Optional outdoor sensor: regulates the heating temperature automatically
-
D.H.W Stainless steel plate heat exchanger guaranteed for 5 years
|
| Technical Data |
| Power |
| Heating capacity max |
kW |
30,2 |
| Heating capacity max |
Btu/h |
103000 |
| Heating capacity min |
kW |
12 |
| Heating capacity min |
Btu/h |
40900 |
| Usable thermal power max |
kW |
28,1 |
| Usable thermal power max |
Btu/h |
95800 |
| Usable thermal power min |
kW |
10,7 |
| Usable thermal power min |
Btu/h |
36500 |
| Characteristics |
| Heat loss to the casing (DT=50°C) |
% |
0,4 |
| Heat loss through the flue when burner on |
% |
6,7 |
| Heat loss through the flue when burner off |
% |
0,4 |
| Maximum exhaust discharge (natural gas) |
kg/h |
65.0 |
| Exhaust gas temperature at nominal capacity |
°C |
0123,8 |
| Minimum ambient temperature |
°C |
5 |
| Gas inlet pressure - Natural Gas (G20) |
mbar |
20 |
| Gas inlet pressure - LPG (G30) |
mbar |
28 |
| Gas inlet pressure - LPG (G31) |
mbar |
30 |
| Residual discharge head |
mbar |
1,4 |
| Pressure loss through boiler (max) (DT=20°C) |
mbar |
200 |
| Maximum heating pressure |
bar |
3 |
| Maximum water content of system |
l |
130 |
| Built-in expansion vessel pre-charge pressure |
bar |
1 |
| Maximum domestic hot water pressure |
bar |
6 |
| Minimum domestic hot water pressure |
bar |
0,2 |
| D.H.W minimum flow rate |
l/min |
2,5 |
| Built-in expansion vessel capacity |
l |
6 |
| Gas consumption at nominal capacity G20 (15°C; 1013 mbar) |
m³/h |
3,19 |
| Gas consumption G30 (15°C; 1013 mbar) |
kg/h |
2,38 |
| Gas consumption G31 (15°C; 1013 mbar) |
kg/h |
2,34 |
| Heigth |
mm |
700 |
| Width |
mm |
400 |
| Depth |
mm |
300 |
| Performance |
| Maximum heating temperature |
°C |
82 |
| Minimum heating temperature |
°C |
38 |
| Maximum domestic hot water temperature |
°C |
56 |
| Minimum domestic hot water temperature |
°C |
36 |
| D.H.W flow rate (DT=35°C) |
gal/min |
2,5 |
| Electrical data |
| Supply voltage |
V |
230 |
| Power consumption |
W |
125 |
| Protection grade of electrical system |
IP |
X4D |
| Internal fuse rating |
|
FAST 2 AT |
Technical Drawing
Legend:
A Central heating flow Ø 3/4" BSP B Domestic hot water outlet Ø 1/2"" BSP C Gas inlet Ø 3/4" BSP D Domestic hot water inlet Ø 1/2" BSP E Central heating return Ø 3/4" BSP F Flue (Ø mm)
|
Residual Head |
|
(Image not available)
|
|
|
|
Hydraulic Schematic |
|
Legend:
ACentral heating flow Ø 3/4" BSP B Domestic hot water outlet Ø 1/2"" BSP C Gas inlet Ø 3/4" BSP D Domestic hot water inlet Ø 1/2" BSP E Central heating return Ø 3/4" BSP F Flue (Ø mm) | |