0 item(s) in a bag  Total: £0.00- Checkout
Home   Careers   Shopping Terms   Contact Us About Us   Links   Order Tracking Invoice Printer   View Shopping Cart  
 Ariston Microgenus II 31 MFFI Boiler
Ariston Microgenus II 31 MFFI Boiler
 
 Price
Your Price:
£0.00
 
Availability: 
Not for Sale
Choose Options & Quantity  
Coaxial Systems 60/100 Horizontal Coaxial Kit - 1000mm [+£57.53]
Horizontal Coaxial Kit + Vertical Starter [+£60.40]
90 Degrees Coaxial Elbow [+£30.20]
45 Degrees Coaxial Elbow (pack of 2) [+£50.34]
Coaxial Extension - 1000mm [+£32.41]
Coaxial Extension - 500mm [+£19.65]
Coaxial Systems 80/125 Horizontal Coaxial Kit + Adaptor 80/125 [+£54.36]
90 Degrees Coaxial Elbow 80/125 [+£36.24]
45 Degrees Coaxial Elbow 80/125 [+£30.20]
Coaxial Extension 80/125 - 1000mm [+£48.32]
Coaxial Extension 80/125 - 500mm [+£34.23]
 Description
Ariston Microgenus II 31 MFFI Boiler

     
 
Compact wall-hung gas combination boiler, room sealed combustion chamber
24,6 kW / 83900 Btu/h, Fan flued, Natural Gas

microGENUS II combines the most advanced heating and domestic hot water production technologies in one compact unit, with tiny dimentions of just 700 x 400 x 300 mm, it can be installed almost anywhere.

Reliable, quiet, durable and hard working, this boiler looks great and offers three different outputs to suit most needs.

Guarantee:
2 Year Guarantee (extended up to 5 years).
 
Main Technical Information
Usable thermal power max
kW
31 
Heigth
mm
700
Width
mm
400
Depth
mm
300
 
Main Characteristics
 Electronic ignition
 Anti-scale device
 Anti-frost device
 Insufficient system pressure shutdown
 Automatic bypass
 High head pump
 Fully modulating
 C.H. Temperature adjustment
 D.H.W Temperature adjustment
 D.H.W plate heat exchanger
 P.C.B with Microprocessor
 Combustion analysis device
 IPX 4D
 Integral auto-diagnostics
 
 
Characteristics

 
 
  • Compact dimentions (300x400x700mm)
  • Available in 3 outputs of 24.6 kW, 28.1 kW and 31.0 kW
  • Fully modulating in C.H./D.H.W. with an accuracy to
  • Auto-diagnostic system and integrated control in P.C.B
  • Government standard assessment procedure (SAP) efficiency rating up to 80.3%
  • Comfort Switch (pre heat function) guaranteeing hot water at the outlet in less than 5 seconds
  • High D.H.W flow rates up to 12.7 l/min (2.8 gal/min) (31 kW - 105800 Btu/h version)
  • Anti-frot device
  • Anti-scale device
  • Anti-seizing device for the pump
  • Built-in mechanical time clock
  • Coaxial flue system up to 4m, twin pipe system up to 30m
  • split exhust and intake pipes for built-in combustion analysis
  • Optional outdoor sensor: regulates the heating temperature automatically
  • D.H.W Stainless steel plate heat exchanger guaranteed for 5 years
 
 Internal View
 
 
Legend:
 
Technical Data
Power
   Heating capacity max kW    33,5
   Heating capacity max Btu/h    114300
   Heating capacity min kW    14
   Heating capacity min Btu/h    47700
   Usable thermal power max kW    31
   Usable thermal power max Btu/h    105800
   Usable thermal power min kW    12,6
   Usable thermal power min Btu/h    43000
Characteristics
   Heat loss to the casing (DT=50°C) %    1,1
   Heat loss through the flue when burner on %    6,5
   Heat loss through the flue when burner off %    0,4
   Maximum exhaust discharge (natural gas) kg/h 74.3
   Exhaust gas temperature at nominal capacity °C    0132,1
   Minimum ambient temperature °C    5
   Gas inlet pressure - Natural Gas (G20) mbar    20
   Gas inlet pressure - LPG (G30) mbar    28
   Gas inlet pressure - LPG (G31) mbar    30
   Residual discharge head mbar    1,6
   Pressure loss through boiler (max) (DT=20°C) mbar    200
   Maximum heating pressure bar    3
   Maximum water content of system l    130
   Built-in expansion vessel pre-charge pressure bar    1
   Maximum domestic hot water pressure bar 6
   Minimum domestic hot water pressure bar    0,2
   D.H.W minimum flow rate l/min    2,5
   Built-in expansion vessel capacity l    6
   Gas consumption at nominal capacity G20 (15°C; 1013 mbar) m³/h    3,54
   Gas consumption G30 (15°C; 1013 mbar) kg/h    2,64
   Gas consumption G31 (15°C; 1013 mbar) kg/h    2,6
   Heigth mm    700
   Width mm    400
   Depth mm    300
Performance
   Maximum heating temperature °C    82
   Minimum heating temperature °C    38
   Maximum domestic hot water temperature °C    56
   Minimum domestic hot water temperature °C    36
   D.H.W flow rate (DT=35°C) gal/min    2,8
Electrical data
   Supply voltage V    230
   Power consumption W    125
   Protection grade of electrical system IP X4D
   Internal fuse rating FAST 2 AT
 
Technical Drawing

Legend:

A Central heating flow Ø 3/4" BSP
B Domestic hot water outlet Ø 1/2"" BSP
C Gas inlet Ø 3/4" BSP
D Domestic hot water inlet Ø 1/2" BSP
E Central heating return Ø 3/4" BSP
F Flue (Ø mm)

Residual Head


(Image not available)

 

 Hydraulic Schematic

 

Legend:

ACentral heating flow Ø 3/4" BSP
B Domestic hot water outlet Ø 1/2"" BSP
C Gas inlet Ø 3/4" BSP
D Domestic hot water inlet Ø 1/2" BSP
E Central heating return Ø 3/4" BSP
F Flue (Ø mm)

 Feature 9
F20

 
 