 HE SLIM Duplex Stainless Steel Ultrasteel Hi Pressure Hot water Cylinder 175 Litre Indirect 1281mm High X 550mm Diameter MegaFlow Type
HE SLIM Duplex Stainless Steel Ultrasteel Hi Pressure Hot water Cylinder 175 Litre Indirect 1281mm High X 550mm Diameter MegaFlow Type
HE SLIM Duplex Stainless Steel Ultrasteel Hi Pressure Hot water Cylinder 175 Litre Indirect 1281mm High X 550mm Diameter MegaFlow Type
 
 Price
Your Price:
£905.21
 
Choose Options & Quantity  
Twin coil upgrade from standard Twin Coil cylinder upgrade [+£293.75]
Quantity
 Description

HE SLIM Duplex Stainless Steel Ultrasteel Hi Pressure Hot water Cylinder 175 Litre Indirect 1281mm High X 550mm Diameter MegaFlow Type

 
 25 year guarantee
 
 
Product Features
 
  • RMC Group Indirect 175L Cylinder
  • Inlet Control set
  • Temperature & Pressure relief valve
  • 15mm / 22mm Tundish
  • Expansion Vessel
  • Expansion vessel bracket
  • 22mm compression connections (DZR)
  • Drain (DZR)
  • 1 x 15mm end feed tee
  • Expansion vessel hose
  • 1 x Immersion Heater (2 on 250ltr & 300ltr)
  • Two port valve
  • Wiring Centre
  • Dual Thermostat
  • Installation & Maintenance Instructions
  • Benchmark Log Book

 

 
 
 
Installation guides
 
 
 

 

 

The RCM Group
 
The RCM Group is now the largest manufacturer of cylinders in the UK and has used the same blueprint for its success in the development and production of its new stainless steel unvented range of cylinders.

 

They are designed specifically for the UKmarket made from high quality 'Duplex' stainless steel, backed by a fully transferable 25 year guarantee.


Technical Data and Diagram 
 
 


 
 
What is mainspressure?

These units allow you to connect the Ultrasteel directly to the mains via the safety valves provided. This allows you to have power showers without the need for noisy shower pumps and means no cold water cistern tanks are required in the loft.
 
Ease of installation

The unit comes with a full, easy-to-follow fitting instruction booklet and all the components you will need. All the connections are at the front of the unit within a 90o arc. The unit can be sited almost anywhere, including the garage.This gives you the added advantage of 100% usable hot water and means that possibly a smaller sized unit can be used to achieve the required literage.
 
Duplex stainless steel for ultimate
peace of mind


The Ultrasteel is manufactured from highest quality Duplex stainless steel. Care must be taken not to confuse this high performance metal with the inferior grades employed by some of our competitors. This type of steel is far more resistant to corrosion than glass lined models and therefore offers a much longer life. Consequently, no anode is required. Duplex stainless steel provides for a much lighter and easier to handle unit.
 
High flow rated controls deal with multiple hot water applications

Our standard valves offer exceptional flow rates and deal with most domestic applications. Larger valve options are also available for industrial and commercial use by special order.
 
Fast reheat and thick insulation means
cheap to run


The coil is designed to heat the whole of the cylinder contents and sits very low in the base of the unit (unlike conventional coils). Add to this the coils large surface area and a very fast recovery is achieved on 100% of its volume. High heat retention is then achieved by use of 50mm thick
CFC/HCFC Free (ODP ZERO) lagging.
 
Reasons for external expansion

When developing Ultrasteel, we drew on all our group’s experience of previous unvented products we had manufactured. Earlier mains pressure
units included both internal and external expansions and, with this knowledge, we have listed below our reasons for having no hesitation in going with an external system.

Unvented cylinders with Internal expansion are known by the trade as “bubble tops”. This is an apt description as they do indeed trap a bubble
of air in the top. As the cylinder is heated up, the expansion of the hot water is taken up by the bubble.

As you probably know water under pressure absorbs air. Some people will be familiar with milky water coming from their taps. The milkyness is
the bubbles in the water formed as the air is released.

In some areas of the countr y, local conditions have led to some bubble top unvented cylinders losing their bubble prematurely. This has been
disruptive and costly for all concerned. Indeed, some have even been converted to external expansion to solve such local problems.

If the air bubble is lost, it is usually necessary to drain down the unit and refill it. As anyone with a water meter will tell you, refilling it costs money
and then the additional inconvenience of having to pay to heat the water again. You would be even more upset if you had to find and pay for a
plumber to do this for you.

Contrast this with the rubber diaphragm inside our expansion vessels. This diaphragm separates the water from the air - PROBLEMSOLVED.
The pressure can easily be checked and topped up with a foot-pump without losing a drop of water.

Add the additional flexibility of remote siting that an expansion vessel brings and the choice for us was clear - External Expansion.


Below are a number of examples, along with data to help you decide which unit is right for you.

There are a number of points to consider along the way - firstly, how many major outlets for hot water do you have to supply?

Baths require between 55 and 100 litres,Jacuzzis require up to 550 litres. (Baths allow 30 minutes duration).

Small Showers require 7 litres per minute,
High Volume Showers require 11 litres per minute.

(Showers allow 10 minutes duration). Sinks require between 10 and 15 litres, Wash Basins require between 1 and 5 litres.

 

Direct
Indirect
Application   Commercial Selection Guide  
Indirect
120L
90L
Flat   Large House 6 Bed / 4 Bathrooms
2 x 210L
150L
120L
1/2 Bed (1 bath/shower)   Guest House 8 Bed / 4 Bathrooms
2 x 300L
180L
150L
3 Bed (1 bath/shower)   Small Hotel 8 Bed / 8 Bathrooms
3 x 210L
210L
180L
4 Bed (1 bath/shower)   Sports Pavilion 25 People / 4 Showers
2 x 300L
250L
210L
4/5 Bed (2 baths/showers)   Sports Pavilion 25 People / 6 Showers
3 x 210L
300L
250L
4/6 Bed (3 baths/showers)   Student House 25 People / 3 Bathrooms
3 x 300L
-
300L
5/6 Bed (3 baths/showers)   Old People's Home 60 Bed / 10 Bathrooms
5 x 300L

 

Reheat Performance
Finally, you have to estimate the number of times any one of these outlets will be used before the unit has time to recover.

Indirect
Re-heat
Coil kW
Direct
Re-heat Time
Re-Heat Time
One Element
Two Element
90L
13 Mins
16.5
90L
58 Mins
-
120L
17 Mins
16.5
120L
90 Mins
45 Mins
150L
17 Mins
18.9
150L
121 Mins
61 Mins
180L
21 Mins
18.9
180L
157 Mins
79 Mins
210L
22 Mins
18.9
210L
192 Mins
96 Mins
250L
28 Mins
21.4
250L
224 Mins
112 Mins
300L
36 Mins
21.4
300L
263 Mins
132 Mins


The reheat performance is measured from 15°C to 60°C after drawing off 70% of the capacity.
The coil kW rating is a guide to the minimum size of boiler required to achieve the reheat times stated. Faster reheat times are achievable using twin-coil Ultrasteel units. With both coils fed simultaneously, reheat times can be reduced to almost half. The boiler power required would double.


Using Ultrasteel units in parallel

For applications where very high flowrate or larger amounts of storage are required two or more Ultrasteel units can be linked in parallel.

When linking two cylinders a seperate cold feed is taken to each one and the outlets are joined together. The flowrate available doubles (subject to the cold main).
The demand for hot water will vary considerably between types of buildings and activities taking place there, for example

An office building will require small quantities frequintly to many outlets during normal and overtime office hours.

A factory production line will have a peak demand at the breaks in the shift or at the end when the work force may all want to wash their hands simultaneously.

A sports pavilion will need to be able to provide large quantities of hot water for the teams showering needs, over a short period of time after the game.

So your selection must take into account a number of things

1) The maximum simultaneous hot wwater demand
2) The total hot water demand required
3) The required system reheat time


 

Taking Responsibility
 
We are very aware of of our long term responsibility to the planet and are doing everything possible to improve our contribution to this cause. We have chosen materials that will genuinely last a lifetime and have avoided producing the steel and glass lined units favoured by other manufacturers which typically offer a much reduced life expectancy.
Duplex stainless steel is extremely environmentally friendly. As a material it is 100% recyclable in fact over 90% of new stainless steel comes from old re-melted stainless steel. Stainless steel will go on to complete full life cycles indefinitely.
The performance of the unit with its “coil within a coil” gives fast recovery to 100% of the water content of the unit and not just part volumes like many on the market. Link this with our 50mm
CFC/HCFC free (ODP Zero) foam injection lagging which gives maximum heat retention and you have a range that is very efficient and will save money on fuel bills.

Being Committed
 
Our commitment goes much further than just the present, as we are constantly developing new products in the same vein. These products go towards developing renewable energy resources such as solar, wind and geothermic power which we can utilise with our high recovery twin coiled units.
Continually Evolving
 
All in all we take environmental issues very seriously when others just pay it lip service, and we will continue to improve and develop our processes and products to keep our self-imposed high standards in this field.

 

 
 

  Add a Review
Name:   Email:  
Location:  
Title:

 

Review: 
Rating:        
= Required
Site Map